Skip to content

Specification Review

globe valve vs gate valve

Resolve globe valve vs gate valve before selecting a supplier. The decision is duty and access, not a catalog synonym. A gate is typically specified for isolation with a low pressure-drop preference when the disc is fully open. A globe is typically specified when the buyer needs characterized throttling or a defined seating stroke. Neither type is released by this page as interchangeable. Maintenance access for a pressure-seal bonnet and the actuator orientation against the piping layout must be written before award.

Decision topic: Decision dependencies

specification review evidence review

Decision dependencies

  1. Input dependency

    Required input
    Buyer-owned isometric or sketch showing end connection, face-to-face, stem or actuator centerline, and the overhead or side access needed to service a pressure-seal bonnet. Fluid, working pressure, temperature and duty cycle travel with that sketch.
    Owner
    The buyer or the buyer’s process engineer owns the duty and layout. Globe Valve Sourcing restates those inputs; it does not invent missing access dimensions.
  2. Review dependency

    • Named manufacturer confirms whether a globe or a gate is being offered, what access the bonnet needs, and which end connection and actuator orientation match the piping layout.
    • Unresolved question: if the layout cannot accept the stem height of a pressure-seal globe, is a bolted-bonnet globe or a gate the intended substitute, and is that substitution labeled?

Close the globe-versus-gate unknowns before awarding

Discuss Your Requirements